Water Reclaim Systems

The PurWater system is a perfect combination of function and form, incorporating the versatility of variable Frequency Drive Technology operated by a Programmable Logic Controller. The patent pending PurWater Succession Self Purging Filtration Technology is a totally physical process that eliminates the need and ongoing expense of antiquated bag or disposable filters while providing the Operator with a consistent production of optimum engineered certified 5 micron product water for his or her specific wash application.

The PurWater system has also successfully addressed the issues of odor typically associated with reclaiming wash water utilizing the same innovative thinking that has become synonymous with the New Wave name. The PurWater system offers several options for odor control starting with our exclusive patent pending chemical-free Air Sparger Odor Control system, Enzyme or Ozone systems.

PW FLOOD SERIES CS-3AS

 

  • 3HP SELF PRIMING PUMP 
  • SAND CYCLONIC SEPARATOR
  • CONTROL SIGNAL ACTIVATION
  • AIR SPARGER
  • POWDER COATED FRAME 
  • 70 MICRON WATER OUTPUT 

RECLAIM MAX. OUTPUT
60 GPM

RECLAIM PUMP
3 HP STA-RITE PUMP-AMP DRAW AT (208/230 VOLT - 8.5)
3 HP STA-RITE PUMP-AMP DRAW AT (460/480 VOLT = 4)

PUMP VOLTAGE
208-230 VOLTS OR 460-480 VOLTS (DEPENDING ON SITE SPECIFICATIONS CAN BE ORDERED EITHER WAY)

DIMENSIONS
44" WIDTH X 38" TALL X 21" DEEP

NET (CRATED) WEIGHT
400 LBS

WATER REQUIREMENTS (PVC)
(2) 2" PVC SUCTION LINES, ONE FOR USE AND ONE FOR SPARE, TO COME UP FROM SETTLING TANKS TO THE RIGHT OF THE RECIRCULATION WITH 2" PVC FULL FLAPPER CHECK VALUES AT END, 2" UNIONS ABOVE WATER LINE.
(1) 1 1/2" LINE OUT TO THE WASH MANIFOLD
(1) 1" LINE TO RETURN TO THE SECOND CHAMBER OF THE RECLAIM TANK FOR AIR SPARGER ODOR CONTROL
(1) 1" LINE TO RETURN TO THE CATCH BASIN FOR THE UNDERFLOW OF THE PURWATER SUCCESSION FILTERS

ELECTRICAL REQUIREMENTS

RECLAIM PUMP
(1) 208/230 VOLT OR 460/480 VOLT 20 AMP THREE PHASE CIRCUITS TO BE HAND WIRED 5 FEET UP FROM THE FLOOR TO THE RIGHT OF THE SYSTEM

(PLC) - LOGIC CONTROLLER
(1) 120 VOLT 20 AMP SINGLE PHASE

CONDUIT
(1) 1" CONDUIT FROM RECLAIM EQUIPMENT CONTROL BOX TO FRONT OF THE LAST TANK (FOR FLOATS)
(1) 1/2" CONDUIT FROM EACH CARWASH EQUIPMENT CONTROL BOX TO SEND CONTROL VOLTAGE SIGNAL TO PURWATER'S REPRESSURIZATION POWER BOX, CONTROL WIRING FROM CARWASH CONTROLLER (110V IS DEFAULT) TO BE WIRED INTO CONTROL BOX ON FRAME

TANK CONFIGURATION RECOMMENDATION
DOUBLE TANK CONFIGURATION (UNDERGROUND - 1500 GALLONS EACH)

 
PW FLOOD SERIES CS-5AS
  • 5 HP SELF PRIMING PUMP 
  • SAND CYCLONIC SEPARATOR
  • CONTROL SIGNAL ACTIVATION
  • AIR SPARGER
  • POWDER COATED FRAME 
  • 70 MICRON WATER OUTPUT 
RECLAIM MAX. OUTPUT
100 GPM

RECLAIM PUMP 
5 HP STA-RITE PUMP-AMP DRAW AT (208/230 VOLT - 12) 
5 HP STA-RITE PUMP-AMP DRAW AT (460/480 VOLT = 6)

PUMP VOLTAGE
208-230 VOLTS OR 460-480 VOLTS (DEPENDING ON SITE SPECIFICATIONS CAN BE ORDERED EITHER WAY)

DIMENSIONS
44" WIDTH X 38" TALL X 21" DEEP

NET (CRATED) WEIGHT
400 LBS

WATER REQUIREMENTS (PVC)
(2) 2" PVC SUCTION LINES, ONE FOR USE AND ONE FOR SPARE, TO COME UP FROM SETTLING TANKS TO THE RIGHT OF THE RECIRCULATION WITH 2" PVC FULL FLAPPER CHECK VALUES AT END, 2" UNIONS ABOVE WATER LINE.
(1) 1 1/2" LINE OUT TO THE WASH MANIFOLD
(1) 1" LINE TO RETURN TO THE SECOND CHAMBER OF THE RECLAIM TANK FOR AIR SPARGER ODOR CONTROL
(1) 1" LINE TO RETURN TO THE CATCH BASIN FOR THE UNDERFLOW OF THE PURWATER SUCCESSION FILTERS

ELECTRICAL REQUIREMENTS

RECLAIM PUMP

(1) 208/230 VOLT OR 460/480 VOLT 20 AMP THREE PHASE CIRCUITS TO BE HAND WIRED 5 FEET UP FROM THE FLOOR TO THE RIGHT OF THE SYSTEM

(PLC) - LOGIC CONTROLLER
(1) 120 VOLT 20 AMP SINGLE PHASE

CONDUIT
(1) 1" CONDUIT FROM RECLAIM EQUIPMENT CONTROL BOX TO FRONT OF THE LAST TANK (FOR FLOATS)
(1) 1/2" CONDUIT FROM EACH CARWASH EQUIPMENT CONTROL BOX TO SEND CONTROL VOLTAGE SIGNAL TO PURWATER'S REPRESSURIZATION POWER BOX, CONTROL WIRING FROM CARWASH CONTROLLER (110V IS DEFAULT) TO BE WIRED INTO CONTROL BOX ON FRAME

TANK CONFIGURATION RECOMMENDATION
DOUBLE TANK CONFIGURATION (UNDERGROUND - 1500 GALLONS EACH)

return to top  

PW 100-5MAS
  • VFD DRIVEN CONTINUOUS DUTY MOTOR 
  • SELF PRIMING PUMP 
  • HIGH EFFICIENCY CYCLONIC SEPARATORS 
  • CONTROL SIGNAL ACTIVATION 
  • 5 MICRON WATER OUTPUT 
  • CONTINUOUS SPARGING RECIRCULATION TECHNOLOGY FOR ODOR CONTROL 
  • POWDER COATED FRAME 
  • ODOR CONTROL OPTIONS
RECLAIM MAX. OUTPUT
30 GPM

RECLAIM PUMP

3 HP SELF-PRIMING CENTRIFUGAL PUMP
DRAWS 8.5 AMPS AT 208/230 VAC OR
DRAWS 4.0 AMPS AT 460/480 VAC
CUSTOMER TO SPECIFY VOLTAGE

DIMENSIONS

48" WIDTH X 74" TALL X 16" DEEP

NET (CRATED) WEIGHT
700 LBS

PLUMBING CONNECTIONS
TWO 2" PVC SUCTION LINES, ONE FOR USE AND ONE FOR SPARE, TO COME UP FROM SETTLING TANKS TO THE RIGHT OF THE RECIRCULATION WITH 2" PVC FULL FLAPPER CHECK VALUES AT END 2" UNIONS ABOVE WATER LINE. 
ONE 1 1/2" LINE OUT TO THE WASH MANIFOLD
ONE 1" LINE TO RETURN TO THE SECOND CHAMBER OF THE RECLAIM TANK FOR AIR SPARGER ODOR CONTROL
ONE 1" LINE TO RETURN TO THE CATCH BASIN FOR THE UNDERFLOW OF THE PURWATER SUCCESSION FILTERS
ONE (1) 1" CITY WATER LINE TO PROVIDE FRESH WATER BY-PASS AND SELF-PRIMING FUNCTION
CITY WATER REQUIRED IS 30 GPM @ 40 PSIG

ELECTRICAL REQUIREMENTS

ONE (1) 208/230 VAC OR 460/480 VAC
3 PHASE, 20 AMP CIRCUIT AND
ONE (1) 120 VAC, 1 PHASE, 20 AMP CIRCUIT

CONDUIT

(1) 1" CONDUIT FROM RECLAIM EQUIPMENT CONTROL BOX TO FRONT OF THE LAST TANK (FOR FLOATS)
(1) 1/2" CONDUIT FROM EACH CARWASH EQUIPMENT CONTROL BOX TO SEND CONTROL VOLTAGE SIGNAL TO PURWATER'S REPRESSURIZATION POWER BOX, CONTROL WIRING FROM CARWASH CONTROLLER (110V IS DEFAULT) TO BE WIRED INTO CONTROL BOX ON FRAME

TANK CONFIGURATION RECOMMENDATION

DOUBLE TANK CONFIGURATION

 

 
PW 200-5MAS
  • VFD DRIVEN CONTINUOUS DUTY MOTOR 
  • SELF PRIMING PUMP 
  • HIGH EFFICIENCY CYCLONIC SEPARATORS 
  • CONTROL SIGNAL ACTIVATION 
  • 5 MICRON WATER OUTPUT 
  • CONTINUOUS SPARGING RECIRCULATION    TECHNOLOGY FOR ODOR CONTROL 
  • POWDER COATED FRAME 
  • ODOR CONTROL OPTIONS
RECLAIM MAX. OUTPUT
60 GPM

RECLAIM PUMP

5 HP SELF-PRIMING CENTRIFUGAL PUMP
DRAWS 12.2 AMPS AT 208/230 VAC OR
DRAWS 6.1 AMPS AT 460/480 VAC
CUSTOMER TO SPECIFY VOLTAGE

DIMENSIONS

48" WIDTH X 74" TALL X 16" DEEP

NET (CRATED) WEIGHT
700 LBS

PLUMBING CONNECTIONS
TWO (2) 3" PVC SUCTION LINES, ONE FOR USE AND ONE FOR SPARE, TO COME UP FROM SETTLING TANKS TO THE RIGHT OF THE RECIRCULATION WITH 2" PVC FULL FLAPPER CHECK VALUES AT END 2" UNIONS ABOVE WATER LINE. 
ONE 2" LINE OUT TO THE WASH MANIFOLD 
ONE 1" LINE TO RETURN TO THE SECOND CHAMBER OF THE RECLAIM TANK FOR AIR SPARGER ODOR CONTROL 
ONE 1" LINE TO RETURN TO THE CATCH BASIN FOR THE UNDERFLOW OF THE PURWATER SUCCESSION FILTERS
ONE (1) 2" CITY WATER LINE TO PROVIDE FRESH WATER BY-PASS AND SELF-PRIMING PUMP FUNCTION
CITY WATER REQUIRED IS 60 GPM @ 40 PSIG

ELECTRICAL REQUIREMENTS

ONE (1) 208/230 VAC OR 460/480 VAC
2 PHASE, 20 AMP CIRCUIT
ONE (1) 120 VAC, 1 PHASE, 20 AMP CIRCUIT

CONDUIT
ONE (1) 1" CONDUIT FROM RECLAIM EQUIPMENT CONTROL BOX TO FRONT OF THE LAST TANK (FOR FLOATS) 
ONE (1) 1/2" CONDUIT FROM EACH CARWASH EQUIPMENT CONTROL BOX TO SEND CONTROL VOLTAGE SIGNAL TO PURWATER'S REPRESSURIZATION POWER BOX, CONTROL WIRING FROM CARWASH CONTROLLER (110V IS DEFAULT) TO BE WIRED INTO CONTROL BOX ON FRAME

TANK CONFIGURATION RECOMMENDATION

TRIPLE TANK CONFIGURATION

 

 
PW 200-5MB
  • VFD DRIVEN CONTINUOUS DUTY MOTOR 
  • SELF PRIMING PUMP 
  • HIGH EFFICIENCY CYCLONIC SEPARATORS 
  • CONTROL SIGNAL ACTIVATION 
  • 5 MICRON WATER OUTPUT 
  • CONTINUOUS SPARGING RECIRCULATION    TECHNOLOGY FOR ODOR CONTROL 
  • POWDER COATED FRAME 
  • ODOR CONTROL OPTIONS
  • ENZYME INJECTION

RECLAIM MAX. OUTPUT

60 GPM

RECLAIM PUMP

5 HP SELF-PRIMING CENTRIFUGAL PUMP
DRAWS 12.2 AMPS AT 208/230 VAC OR
DRAWS 6.1 AMPS AT 460/480 VAC
CUSTOMER TO SPECIFY VOLTAGE

DIMENSIONS

48" WIDTH X 74" TALL X 16" DEEP

NET (CRATED) WEIGHT
700 LBS

PLUMBING CONNECTIONS
TWO (2) 3" PVC SUCTION LINES, ONE FOR USE AND ONE FOR SPARE, TO COME UP FROM SETTLING TANKS TO THE RIGHT OF THE RECIRCULATION WITH 2" PVC FULL FLAPPER CHECK VALUES AT END 2" UNIONS ABOVE WATER LINE. 
ONE 2" LINE OUT TO THE WASH MANIFOLD 
ONE 1" LINE TO RETURN TO THE SECOND CHAMBER OF THE RECLAIM TANK FOR AIR SPARGER ODOR CONTROL 
ONE 1" LINE TO RETURN TO THE CATCH BASIN FOR THE UNDERFLOW OF THE PURWATER SUCCESSION FILTERS
ONE (1) 2" CITY WATER LINE TO PROVIDE FRESH WATER BY-PASS AND SELF-PRIMING PUMP FUNCTION
CITY WATER REQUIRED IS 60 GPM @ 40 PSIG

ELECTRICAL REQUIREMENTS

ONE (1) 208/230 VAC OR 460/480 VAC
2 PHASE, 20 AMP CIRCUIT
ONE (1) 120 VAC, 1 PHASE, 20 AMP CIRCUIT

CONDUIT
ONE (1) 1" CONDUIT FROM RECLAIM EQUIPMENT CONTROL BOX TO FRONT OF THE LAST TANK (FOR FLOATS) 
ONE (1) 1/2" CONDUIT FROM EACH CARWASH EQUIPMENT CONTROL BOX TO SEND CONTROL VOLTAGE SIGNAL TO PURWATER'S REPRESSURIZATION POWER BOX, CONTROL WIRING FROM CARWASH CONTROLLER (110V IS DEFAULT) TO BE WIRED INTO CONTROL BOX ON FRAME

TANK CONFIGURATION RECOMMENDATION

TRIPLE TANK CONFIGURATION

 

 
PW 200-5M12O
  • VFD DRIVEN CONTINUOUS DUTY MOTOR 
  • SELF PRIMING PUMP 
  • HIGH EFFICIENCY CYCLONIC SEPARATORS 
  • CONTROL SIGNAL ACTIVATION 
  • 5 MICRON WATER OUTPUT 
  • CONTINUOUS SPARGING RECIRCULATION    TECHNOLOGY FOR ODOR CONTROL 
  • POWDER COATED FRAME 
  • ODOR CONTROL OPTIONS

RECLAIM MAX. OUTPUT

60 GPM

RECLAIM PUMP

5 HP SELF-PRIMING CENTRIFUGAL PUMP
DRAWS 12 AMPS AT 208/230 VAC OR
DRAWS 6 AMPS AT 460/480 VAC
CUSTOMER TO SPECIFY VOLTAGE

DIMENSIONS

48" WIDTH X 84" TALL X 16" DEEP

NET (CRATED) WEIGHT
800 LBS

PLUMBING CONNECTIONS
TWO (2) 2" PVC SUCTION LINES, ONE FOR USE AND ONE FOR SPARE, TO COME UP FROM SETTLING TANKS TO THE RIGHT OF THE RECIRCULATION WITH 2" PVC FULL FLAPPER CHECK VALUES AT END 2" UNIONS ABOVE WATER LINE. 
ONE 2" LINE OUT TO THE WASH MANIFOLD
ONE 1" LINE TO RETURN TO THE SECOND CHAMBER OF THE RECLAIM TANK FOR OZONE ODOR CONTROL
ONE 1" LINE TO RETURN TO THE CATCH BASIN FOR THE UNDERFLOW OF THE PURWATER SUCCESSION FILTERS
ONE (1) 2" CITY WATER LINE TO PROVIDE FRESH WATER BY-PASS AND SELF-PRIMING FUNCTION
CITY WATER REQUIRED IS 60 GPM @ 40 PSIG

ELECTRICAL REQUIREMENTS

ONE (1) 208/230 VAC OR 460/480 VAC
3 PHASE, 20 AMP CIRCUIT AND
ONE (1) 120 VAC, 1 PHASE, 20 AMP CIRCUIT

CONDUIT

(1) 1" CONDUIT FROM RECLAIM EQUIPMENT CONTROL BOX TO FRONT OF THE LAST TANK (FOR FLOATS)
(1) 1/2" CONDUIT FROM EACH CARWASH EQUIPMENT CONTROL BOX TO SEND CONTROL VOLTAGE SIGNAL TO PURWATER'S REPRESSURIZATION POWER BOX, CONTROL WIRING FROM CARWASH CONTROLLER (110V IS DEFAULT) TO BE WIRED INTO CONTROL BOX ON FRAME

TANK CONFIGURATION RECOMMENDATION

TRIPLE TANK CONFIGURATION

 

 
PW 200-5M24O
  • VFD DRIVEN CONTINUOUS DUTY MOTOR 
  • SELF PRIMING PUMP 
  • HIGH EFFICIENCY CYCLONIC SEPARATORS 
  • CONTROL SIGNAL ACTIVATION 
  • 5 MICRON WATER OUTPUT
  • CONTINUOUS SPARGING RECIRCULATION    TECHNOLOGY FOR ODOR CONTROL 
  • POWDER COATED FRAME 
  • ODOR CONTROL OPTIONS

RECLAIM MAX. OUTPUT

60 GPM

RECLAIM PUMP

5 HP SELF-PRIMING CENTRIFUGAL PUMP
DRAWS 12 AMPS AT 208/230 VAC OR
DRAWS 6 AMPS AT 460/480 VAC
CUSTOMER TO SPECIFY VOLTAGE

DIMENSIONS

48" WIDTH X 84" TALL X 16" DEEP

NET (CRATED) WEIGHT
800 LBS

PLUMBING CONNECTIONS
TWO (2) 2" PVC SUCTION LINES, ONE FOR USE AND ONE FOR SPARE, TO COME UP FROM SETTLING TANKS TO THE RIGHT OF THE RECIRCULATION WITH 2" PVC FULL FLAPPER CHECK VALUES AT END 2" UNIONS ABOVE WATER LINE. 
ONE 2" LINE OUT TO THE WASH MANIFOLD
ONE 1" LINE TO RETURN TO THE SECOND CHAMBER OF THE RECLAIM TANK FOR OZONE ODOR CONTROL
ONE 1" LINE TO RETURN TO THE CATCH BASIN FOR THE UNDERFLOW OF THE PURWATER SUCCESSION FILTERS
ONE (1) 2" CITY WATER LINE TO PROVIDE FRESH WATER BY-PASS AND SELF-PRIMING FUNCTION
CITY WATER REQUIRED IS 60 GPM @ 40 PSIG

ELECTRICAL REQUIREMENTS

ONE (1) 208/230 VAC OR 460/480 VAC
3 PHASE, 20 AMP CIRCUIT AND
ONE (1) 120 VAC, 1 PHASE, 20 AMP CIRCUIT

CONDUIT

(1) 1" CONDUIT FROM RECLAIM EQUIPMENT CONTROL BOX TO FRONT OF THE LAST TANK (FOR FLOATS)
(1) 1/2" CONDUIT FROM EACH CARWASH EQUIPMENT CONTROL BOX TO SEND CONTROL VOLTAGE SIGNAL TO PURWATER'S REPRESSURIZATION POWER BOX, CONTROL WIRING FROM CARWASH CONTROLLER (110V IS DEFAULT) TO BE WIRED INTO CONTROL BOX ON FRAME

TANK CONFIGURATION RECOMMENDATION

TRIPLE TANK CONFIGURATION

 

 
PW 300-5MAS
  • VFD DRIVEN CONTINUOUS DUTY MOTOR 
  • SELF PRIMING PUMP 
  • HIGH EFFICIENCY CYCLONIC SEPARATORS 
  • CONTROL SIGNAL ACTIVATION 
  • 5 MICRON WATER OUTPUT 
  • CONTINUOUS SPARGING RECIRCULATION TECHNOLOGY FOR ODOR CONTROL 
  • POWDER COATED FRAME 
  • ODOR CONTROL OPTIONS
RECLAIM MAX. OUTPUT
90 GPM

RECLAIM PUMP
 
5 HP SELF-PRIMING CENTRIFUGAL PUMP
DRAWS 12.2 AMPS AT 208/230 VAC OR
DRAWS 6.1 AMPS AT 460/480 VAC
CUSTOMER TO SPECIFY VOLTAGE

DIMENSIONS

48" WIDTH X 74" TALL X 16" DEEP

NET (CRATED) WEIGHT
700 LBS

WATER REQUIREMENTS

TWO 2" PVC SUCTION LINES, ONE FOR USE AND ONE FOR SPARE, TO COME UP FROM SETTLING TANKS TO THE RIGHT OF THE RECIRCULATION WITH 2" PVC FULL FLAPPER CHECK VALUES AT END 2" UNIONS ABOVE WATER LINE. 
ONE 2" LINE OUT TO THE WASH MANIFOLD 
ONE 1" LINE TO RETURN TO THE SECOND CHAMBER OF THE RECLAIM TANK FOR AIR SPARGER ODOR CONTROL 
ONE 1" LINE TO RETURN TO THE CATCH BASIN FOR THE UNDERFLOW OF THE PURWATER SUCCESSION FILTERS
ONE (1) 2" CITY WATER LINE TO PROVIDE FRESH WATER BY-PASS AND SELF-PRIMING FUNCTION.
CITY WATER REQUIRED IS 90 GPM @ 40 PSIG

ELECTRICAL REQUIREMENTS

ONE (1) 208/230 VAC OR 460/480 VAC
3 PHASE, 20 AMP CIRCUIT AND ONE (1) 120 VAC, 1 PHASE, 20 AMP CIRCUIT

CONDUIT

(1) 1" CONDUIT FROM RECLAIM EQUIPMENT CONTROL BOX TO FRONT OF THE LAST TANK (FOR FLOATS)
(1) 1/2" CONDUIT FROM EACH CARWASH EQUIPMENT CONTROL BOX TO SEND CONTROL VOLTAGE SIGNAL TO PURWATER'S REPRESSURIZATION POWER BOX, CONTROL WIRING FROM CARWASH CONTROLLER (110V IS DEFAULT) TO BE WIRED INTO CONTROL BOX ON FRAME

TANK CONFIGURATION RECOMMENDATION

TRIPLE TANK CONFIGURATION

 

 
PW 300-5MB
  • VFD DRIVEN CONTINUOUS DUTY MOTOR 
  • SELF PRIMING PUMP 
  • HIGH EFFICIENCY CYCLONIC SEPARATORS 
  • CONTROL SIGNAL ACTIVATION 
  • 5 MICRON WATER OUTPUT
  • CONTINUOUS SPARGING RECIRCULATION TECHNOLOGY FOR ODOR CONTROL
  • POWDER COATED FRAME 
  • ODOR CONTROL OPTIONS
RECLAIM MAX. OUTPUT
90 GPM

RECLAIM PUMP
 
5 HP SELF-PRIMING CENTRIFUGAL PUMP
DRAWS 12.2 AMPS AT 208/230 VAC OR
DRAWS 6.1 AMPS AT 460/480 VAC
CUSTOMER TO SPECIFY VOLTAGE

DIMENSIONS

48" WIDTH X 74" TALL X 16" DEEP

NET (CRATED) WEIGHT
700 LBS

WATER REQUIREMENTS

TWO (2) 3" PVC SUCTION LINES, ONE FOR USE AND ONE FOR SPARE, TO COME UP FROM SETTLING TANKS TO THE RIGHT OF THE RECIRCULATION WITH 2" PVC FULL FLAPPER CHECK VALUES AT END 2" UNIONS ABOVE WATER LINE. 
ONE 2" LINE OUT TO THE WASH MANIFOLD 
ONE 1" LINE TO RETURN TO THE SECOND CHAMBER OF THE RECLAIM TANK FOR AIR SPARGER ODOR CONTROL AND ENZYME INJECTION 
ONE 1" LINE TO RETURN TO THE CATCH BASIN FOR THE UNDERFLOW OF THE PURWATER SUCCESSION FILTERS
ONE (1) 2" CITY WATER LINE TO PROVIDE FRESH WATER BY-PASS AND SELF-PRIMING FUNCTION.
CITY WATER REQUIRED IS 90 GPM @ 40 PSIG

ELECTRICAL REQUIREMENTS

ONE (1) 208/230 VAC OR 460/480 VAC
3 PHASE, 20 AMP CIRCUIT AND ONE (1) 120 VAC, 1 PHASE, 20 AMP CIRCUIT

CONDUIT

(1) 1" CONDUIT FROM RECLAIM EQUIPMENT CONTROL BOX TO FRONT OF THE LAST TANK (FOR FLOATS)
(1) 1/2" CONDUIT FROM EACH CARWASH EQUIPMENT CONTROL BOX TO SEND CONTROL VOLTAGE SIGNAL TO PURWATER'S REPRESSURIZATION POWER BOX, CONTROL WIRING FROM CARWASH CONTROLLER (110V IS DEFAULT) TO BE WIRED INTO CONTROL BOX ON FRAME

TANK CONFIGURATION RECOMMENDATION

TRIPLE TANK CONFIGURATION

 

 
PW 300-5M12O
  • VFD DRIVEN CONTINUOUS DUTY MOTOR 
  • SELF PRIMING PUMP 
  • HIGH EFFICIENCY CYCLONIC SEPARATORS 
  • CONTROL SIGNAL ACTIVATION 
  • 5 MICRON WATER OUTPUT 
  • CONTINUOUS SPARGING RECIRCULATION    TECHNOLOGY FOR ODOR CONTROL
  • POWDER COATED FRAME 
  • ODOR CONTROL OPTIONS
RECLAIM MAX. OUTPUT
90 GPM

RECLAIM PUMP

5 HP SELF-PRIMING CENTRIFUGAL PUMP
DRAWS 12 AMPS AT 208/230 VAC OR
DRAWS 6 AMPS AT 460/480 VAC
CUSTOMER TO SPECIFY VOLTAGE

DIMENSIONS

48" WIDTH X 84" TALL X 16" DEEP

NET (CRATED) WEIGHT
800 LBS

PLUMBING CONNECTIONS
TWO (2) 3" PVC SUCTION LINES, ONE FOR USE AND ONE FOR SPARE, TO COME UP FROM SETTLING TANKS TO THE RIGHT OF THE RECIRCULATION WITH 2" PVC FULL FLAPPER CHECK VALUES AT END 2" UNIONS ABOVE WATER LINE. 
ONE 2" LINE OUT TO THE WASH MANIFOLD
ONE 1" LINE TO RETURN TO THE SECOND CHAMBER OF THE RECLAIM TANK FOR OZONE ODOR CONTROL
ONE 1" LINE TO RETURN TO THE CATCH BASIN FOR THE UNDERFLOW OF THE PURWATER SUCCESSION FILTERS
ONE (1) 2" CITY WATER LINE TO PROVIDE FRESH WATER BY-PASS AND SELF-PRIMING FUNCTION
CITY WATER REQUIRED IS 60 GPM @ 40 PSIG

ELECTRICAL REQUIREMENTS

ONE (1) 208/230 VAC OR 460/480 VAC
3 PHASE, 20 AMP CIRCUIT AND
ONE (1) 120 VAC, 1 PHASE, 20 AMP CIRCUIT

CONDUIT

(1) 1" CONDUIT FROM RECLAIM EQUIPMENT CONTROL BOX TO FRONT OF THE LAST TANK (FOR FLOATS)
(1) 1/2" CONDUIT FROM EACH CARWASH EQUIPMENT CONTROL BOX TO SEND CONTROL VOLTAGE SIGNAL TO PURWATER'S REPRESSURIZATION POWER BOX, CONTROL WIRING FROM CARWASH CONTROLLER (110V IS DEFAULT) TO BE WIRED INTO CONTROL BOX ON FRAME

TANK CONFIGURATION RECOMMENDATION

TRIPLE TANK CONFIGURATION

 

 
PW 300-5M24O
  • VFD DRIVEN CONTINUOUS DUTY MOTOR 
  • SELF PRIMING PUMP 
  • HIGH EFFICIENCY CYCLONIC SEPARATORS 
  • CONTROL SIGNAL ACTIVATION 
  • 5 MICRON WATER OUTPUT
  • CONTINUOUS SPARGING RECIRCULATION TECHNOLOGY FOR ODOR CONTROL 
  • POWDER COATED FRAME 
  • ODOR CONTROL OPTIONS
RECLAIM MAX. OUTPUT
90 GPM

RECLAIM PUMP

5 HP SELF-PRIMING CENTRIFUGAL PUMP
DRAWS 12 AMPS AT 208/230 VAC OR
DRAWS 6 AMPS AT 460/480 VAC
CUSTOMER TO SPECIFY VOLTAGE

DIMENSIONS

48" WIDTH X 84" TALL X 16" DEEP

NET (CRATED) WEIGHT
800 LBS

PLUMBING CONNECTIONS
TWO (2) 3" PVC SUCTION LINES, ONE FOR USE AND ONE FOR SPARE, TO COME UP FROM SETTLING TANKS TO THE RIGHT OF THE RECIRCULATION WITH 2" PVC FULL FLAPPER CHECK VALUES AT END 2" UNIONS ABOVE WATER LINE. 
ONE 2" LINE OUT TO THE WASH MANIFOLD
ONE 1" LINE TO RETURN TO THE SECOND CHAMBER OF THE RECLAIM TANK FOR OZONE ODOR CONTROL
ONE 1" LINE TO RETURN TO THE CATCH BASIN FOR THE UNDERFLOW OF THE PURWATER SUCCESSION FILTERS
ONE (1) 2" CITY WATER LINE TO PROVIDE FRESH WATER BY-PASS AND SELF-PRIMING FUNCTION
CITY WATER REQUIRED IS 60 GPM @ 40 PSIG

ELECTRICAL REQUIREMENTS

ONE (1) 208/230 VAC OR 460/480 VAC
3 PHASE, 20 AMP CIRCUIT AND
ONE (1) 120 VAC, 1 PHASE, 20 AMP CIRCUIT

CONDUIT

(1) 1" CONDUIT FROM RECLAIM EQUIPMENT CONTROL BOX TO FRONT OF THE LAST TANK (FOR FLOATS)
(1) 1/2" CONDUIT FROM EACH CARWASH EQUIPMENT CONTROL BOX TO SEND CONTROL VOLTAGE SIGNAL TO PURWATER'S REPRESSURIZATION POWER BOX, CONTROL WIRING FROM CARWASH CONTROLLER (110V IS DEFAULT) TO BE WIRED INTO CONTROL BOX ON FRAME

TANK CONFIGURATION RECOMMENDATION

TRIPLE TANK CONFIGURATION

 

 
PW 350-5MAS
  • VFD DRIVEN CONTINUOUS DUTY MOTOR 
  • SELF PRIMING PUMP 
  • HIGH EFFICIENCY CYCLONIC SEPARATORS 
  • CONTROL SIGNAL ACTIVATION 
  • 5 MICRON WATER OUTPUT 
  • CONTINUOUS SPARGING RECIRCULATION TECHNOLOGY FOR ODOR CONTROL 
  • POWDER COATED FRAME 
  • ODOR CONTROL OPTIONS
RECLAIM MAX. OUTPUT
120 GPM

RECLAIM PUMP

5 HP SELF-PRIMING CENTRIFUGAL PUMP
DRAWS 12.2 AMPS AT 208/230 VAC OR
DRAWS 6.1 AMPS AT 460/480 VAC
CUSTOMER TO SPECIFY VOLTAGE

DIMENSIONS

48" WIDTH X 74" TALL X 16" DEEP

NET (CRATED) WEIGHT
700 LBS

PLUMBING CONNECTIONS
TWO (2) 3" PVC SUCTION LINES, ONE FOR USE AND ONE FOR SPARE, TO COME UP FROM SETTLING TANKS TO THE RIGHT OF THE RECIRCULATION WITH 2" PVC FULL FLAPPER CHECK VALUES AT END 2" UNIONS ABOVE WATER LINE.
ONE 2" LINE OUT TO THE WASH MANIFOLD 
ONE 1" LINE TO RETURN TO THE SECOND CHAMBER OF THE RECLAIM TANK FOR AIR SPARGER ODOR CONTROL 
ONE 1" LINE TO RETURN TO THE CATCH BASIN FOR THE UNDERFLOW OF THE PURWATER SUCCESSION FILTERS
ONE (1) 2" CITY WATER LINE TO PROVIDE FRESH WATER BY-PASS AND SELF-PRIMING FUNCTION.
CITY WATER REQUIRED IS 120 GPM @ 40 PSIG

ELECTRICAL REQUIREMENTS

ONE (1) 208/230 VAC OR OR 460/480 VAC, 3 PHASE, 20 AMP CIRCUIT AND ONE (1) 120 VAC, 1 PHASE, 20 AMP CIRCUIT

CONDUIT

ONE (1) 1" CONDUIT FROM RECLAIM EQUIPMENT CONTROL BOX TO FRONT OF THE LAST TANK (FOR FLOATS)
ONE (1) 1/2" CONDUIT FROM EACH CARWASH EQUIPMENT CONTROL BOX TO SEND CONTROL VOLTAGE SIGNAL TO PURWATER'S REPRESSURIZATION POWER BOX, CONTROL WIRING FROM CARWASH CONTROLLER (110V IS DEFAULT) TO BE WIRED INTO CONTROL BOX ON FRAME

TANK CONFIGURATION RECOMMENDATION

FOUR TANK CONFIGURATION

 

 
PW 350-5MB
  • VFD DRIVEN CONTINUOUS DUTY MOTOR 
  • SELF PRIMING PUMP 
  • HIGH EFFICIENCY CYCLONIC SEPARATORS 
  • CONTROL SIGNAL ACTIVATION 
  • 5 MICRON WATER OUTPUT 
  • CONTINUOUS SPARGING RECIRCULATION TECHNOLOGY FOR ODOR CONTROL 
  • POWDER COATED FRAME 
  • ODOR CONTROL OPTIONS
RECLAIM MAX. OUTPUT
120 GPM

RECLAIM PUMP
 
5 HP SELF-PRIMING CENTRIFUGAL PUMP
DRAWS 12.2 AMPS AT 208/230 VAC OR
DRAWS 6.1 AMPS AT 460/480 VAC
CUSTOMER TO SPECIFY VOLTAGE

DIMENSIONS

48" WIDTH X 74" TALL X 16" DEEP

NET (CRATED) WEIGHT
700 LBS

WATER REQUIREMENTS

TWO (2) 3" PVC SUCTION LINES, ONE FOR USE AND ONE FOR SPARE, TO COME UP FROM SETTLING TANKS TO THE RIGHT OF THE RECIRCULATION WITH 2" PVC FULL FLAPPER CHECK VALUES AT END 2" UNIONS ABOVE WATER LINE. 
ONE 2" LINE OUT TO THE WASH MANIFOLD 
ONE 1" LINE TO RETURN TO THE SECOND CHAMBER OF THE RECLAIM TANK FOR AIR SPARGER ODOR CONTROL AND ENZYME INJECTION 
ONE 1" LINE TO RETURN TO THE CATCH BASIN FOR THE UNDERFLOW OF THE PURWATER SUCCESSION FILTERS
ONE (1) 2" CITY WATER LINE TO PROVIDE FRESH WATER BY-PASS AND SELF-PRIMING FUNCTION.
CITY WATER REQUIRED IS 90 GPM @ 40 PSIG

ELECTRICAL REQUIREMENTS

ONE (1) 208/230 VAC OR 460/480 VAC
3 PHASE, 20 AMP CIRCUIT AND ONE (1) 120 VAC, 1 PHASE, 20 AMP CIRCUIT

CONDUIT

(1) 1" CONDUIT FROM RECLAIM EQUIPMENT CONTROL BOX TO FRONT OF THE LAST TANK (FOR FLOATS)
(1) 1/2" CONDUIT FROM EACH CARWASH EQUIPMENT CONTROL BOX TO SEND CONTROL VOLTAGE SIGNAL TO PURWATER'S REPRESSURIZATION POWER BOX, CONTROL WIRING FROM CARWASH CONTROLLER (110V IS DEFAULT) TO BE WIRED INTO CONTROL BOX ON FRAME

TANK CONFIGURATION RECOMMENDATION

FOUR TANK CONFIGURATION

 

 
PW 350-5M12O
  • VFD DRIVEN CONTINUOUS DUTY MOTOR 
  • SELF PRIMING PUMP 
  • HIGH EFFICIENCY CYCLONIC SEPARATORS 
  • CONTROL SIGNAL ACTIVATION 
  • 5 MICRON WATER OUTPUT 
  • CONTINUOUS SPARGING RECIRCULATION    TECHNOLOGY FOR ODOR CONTROL 
  • POWDER COATED FRAME 
  • ODOR CONTROL OPTIONS
RECLAIM MAX. OUTPUT
120 GPM

RECLAIM PUMP

5 HP SELF-PRIMING CENTRIFUGAL PUMP
DRAWS 12 AMPS AT 208/230 VAC OR
DRAWS 6 AMPS AT 460/480 VAC
CUSTOMER TO SPECIFY VOLTAGE

DIMENSIONS

48" WIDTH X 84" TALL X 16" DEEP

NET (CRATED) WEIGHT
800 LBS

PLUMBING CONNECTIONS
TWO (2) 3" PVC SUCTION LINES, ONE FOR USE AND ONE FOR SPARE, TO COME UP FROM SETTLING TANKS TO THE RIGHT OF THE RECIRCULATION WITH 2" PVC FULL FLAPPER CHECK VALUES AT END 2" UNIONS ABOVE WATER LINE. 
ONE 2" LINE OUT TO THE WASH MANIFOLD
ONE 1" LINE TO RETURN TO THE SECOND CHAMBER OF THE RECLAIM TANK FOR OZONE ODOR CONTROL
ONE 1" LINE TO RETURN TO THE CATCH BASIN FOR THE UNDERFLOW OF THE PURWATER SUCCESSION FILTERS
ONE (1) 2" CITY WATER LINE TO PROVIDE FRESH WATER BY-PASS AND SELF-PRIMING FUNCTION
CITY WATER REQUIRED IS 60 GPM @ 40 PSIG

ELECTRICAL REQUIREMENTS

ONE (1) 208/230 VAC OR 460/480 VAC
3 PHASE, 20 AMP CIRCUIT AND
ONE (1) 120 VAC, 1 PHASE, 20 AMP CIRCUIT

CONDUIT

(1) 1" CONDUIT FROM RECLAIM EQUIPMENT CONTROL BOX TO FRONT OF THE LAST TANK (FOR FLOATS)
(1) 1/2" CONDUIT FROM EACH CARWASH EQUIPMENT CONTROL BOX TO SEND CONTROL VOLTAGE SIGNAL TO PURWATER'S REPRESSURIZATION POWER BOX, CONTROL WIRING FROM CARWASH CONTROLLER (110V IS DEFAULT) TO BE WIRED INTO CONTROL BOX ON FRAME

TANK CONFIGURATION RECOMMENDATION
 
FOUR TANK CONFIGURATION

 

 
PW 350-5M24O
  • VFD DRIVEN CONTINUOUS DUTY MOTOR 
  • SELF PRIMING PUMP 
  • HIGH EFFICIENCY CYCLONIC SEPARATORS 
  • CONTROL SIGNAL ACTIVATION
  • 5 MICRON WATER OUTPUT 
  • CONTINUOUS SPARGING RECIRCULATION    TECHNOLOGY FOR ODOR CONTROL 
  • POWDER COATED FRAME 
  • ODOR CONTROL OPTIONS
RECLAIM MAX. OUTPUT
120 GPM

RECLAIM PUMP

5 HP SELF-PRIMING CENTRIFUGAL PUMP
DRAWS 12 AMPS AT 208/230 VAC OR
DRAWS 6 AMPS AT 460/480 VAC
CUSTOMER TO SPECIFY VOLTAGE

DIMENSIONS

48" WIDTH X 84" TALL X 16" DEEP

NET (CRATED) WEIGHT
800 LBS

PLUMBING CONNECTIONS
TWO (2) 3" PVC SUCTION LINES, ONE FOR USE AND ONE FOR SPARE, TO COME UP FROM SETTLING TANKS TO THE RIGHT OF THE RECIRCULATION WITH 2" PVC FULL FLAPPER CHECK VALUES AT END 2" UNIONS ABOVE WATER LINE. 
ONE 2" LINE OUT TO THE WASH MANIFOLD
ONE 1" LINE TO RETURN TO THE SECOND CHAMBER OF THE RECLAIM TANK FOR OZONE ODOR CONTROL
ONE 1" LINE TO RETURN TO THE CATCH BASIN FOR THE UNDERFLOW OF THE PURWATER SUCCESSION FILTERS
ONE (1) 2" CITY WATER LINE TO PROVIDE FRESH WATER BY-PASS AND SELF-PRIMING FUNCTION
CITY WATER REQUIRED IS 60 GPM @ 40 PSIG

ELECTRICAL REQUIREMENTS

ONE (1) 208/230 VAC OR 460/480 VAC
3 PHASE, 20 AMP CIRCUIT AND
ONE (1) 120 VAC, 1 PHASE, 20 AMP CIRCUIT

CONDUIT

(1) 1" CONDUIT FROM RECLAIM EQUIPMENT CONTROL BOX TO FRONT OF THE LAST TANK (FOR FLOATS)
(1) 1/2" CONDUIT FROM EACH CARWASH EQUIPMENT CONTROL BOX TO SEND CONTROL VOLTAGE SIGNAL TO PURWATER'S REPRESSURIZATION POWER BOX, CONTROL WIRING FROM CARWASH CONTROLLER (110V IS DEFAULT) TO BE WIRED INTO CONTROL BOX ON FRAME

TANK CONFIGURATION RECOMMENDATION

FOUR TANK CONFIGURATION

 

 
PW 400-5MAS
  • VFD DRIVEN CONTINUOUS DUTY MOTOR 
  • SELF PRIMING PUMP 
  • HIGH EFFICIENCY CYCLONIC SEPARATORS 
  • CONTROL SIGNAL ACTIVATION 
  • 5 MICRON WATER OUTPUT 
  • CONTINUOUS SIGNAL ACTIVATION
  • POWDER COATED FRAME 
  • ODOR CONTROL OPTIONS
RECLAIM MAX. OUTPUT
160 GPM

RECLAIM PUMP

10 HP CENTRIFUGAL PUMP
DRAWS 25.7 AMPS AT 208/230 VAC OR
DRAWS 12.9 AMPS AT 460/480 VAC
CUSTOMER TO SPECIFY VOLTAGE

DIMENSIONS

60" WIDTH X 76" TALL X 24" DEEP

NET (CRATED) WEIGHT
1000 LBS 

PLUMBING CONNECTIONS
TWO (2) 3" PVC SUCTION LINES, ONE FOR USE AND ONE FOR SPARE, TO COME UP FROM SETTLING TANKS TO THE RIGHT OF THE RECIRCULATION WITH 2" PVC FULL FLAPPER CHECK VALUES AT END 2" UNIONS ABOVE WATER LINE. 
ONE (1) 2" LINE OUT TO THE WASH MANIFOLD (1) 1" LINE TO RETURN TO THE SECOND CHAMBER OF THE RECLAIM TANK FOR AIR SPARGER ODOR CONTROL 
ONE (1) 1" LINE TO RETURN TO THE CATCH BASIN FOR THE UNDERFLOW OF THE PURWATER SUCCESSION FILTERS
ONE (1) 2" CITY WATER LINE TO PROVIDE FRESH WATER BY-PASS AND SELF-PRIMING FUNCTION.
CITY WATER REQUIRED IS 160 GPM @ 40 PSIG

ELECTRICAL REQUIREMENTS

ONE (1) 208/230 VAC OR 460/480 VAC, 3 PHASE, 30 AMP CIRCUIT AND ONE (1) 120 VAC, 1 PHASE, 20 AMP CIRCUIT

CONDUIT

ONE (1) 1" CONDUIT FROM RECLAIM EQUIPMENT CONTROL BOX TO FRONT OF THE LAST TANK (FOR FLOATS)
ONE (1) 1/2" CONDUIT FROM EACH CARWASH EQUIPMENT CONTROL BOX TO SEND CONTROL VOLTAGE SIGNAL TO PURWATER'S REPRESSURIZATION POWER BOX, CONTROL WIRING FROM CARWASH CONTROLLER (110V IS DEFAULT) TO BE WIRED INTO CONTROL BOX ON FRAME

TANK CONFIGURATION RECOMMENDATION

FOUR TANK CONFIGURATION

 

 
PW 400-5MB
  • VFD DRIVEN CONTINUOUS DUTY MOTOR 
  • SELF PRIMING PUMP 
  • HIGH EFFICIENCY CYCLONIC SEPARATORS 
  • CONTROL SIGNAL ACTIVATION 
  • 5 MICRON WATER OUTPUT 
  • CONTINUOUS SIGNAL ACTIVATION
  • POWDER COATED FRAME 
  • ODOR CONTROL OPTIONS
RECLAIM MAX. OUTPUT
160 GPM

RECLAIM PUMP

10 HP CENTRIFUGAL PUMP
DRAWS 25.7 AMPS AT 208/230 VAC OR
DRAWS 12.9 AMPS AT 460/480 VAC
CUSTOMER TO SPECIFY VOLTAGE

DIMENSIONS

60" WIDTH X 76" TALL X 24" DEEP

NET (CRATED) WEIGHT
1000 LBS 

PLUMBING CONNECTIONS
TWO (2) 3" PVC SUCTION LINES, ONE FOR USE AND ONE FOR SPARE, TO COME UP FROM SETTLING TANKS TO THE RIGHT OF THE RECIRCULATION WITH 2" PVC FULL FLAPPER CHECK VALUES AT END 2" UNIONS ABOVE WATER LINE. 
ONE (1) 2" LINE OUT TO THE WASH MANIFOLD (1) 1" LINE TO RETURN TO THE SECOND CHAMBER OF THE RECLAIM TANK FOR AIR SPARGER ODOR CONTROL 
ONE (1) 1" LINE TO RETURN TO THE CATCH BASIN FOR THE UNDERFLOW OF THE PURWATER SUCCESSION FILTERS
ONE (1) 2" CITY WATER LINE TO PROVIDE FRESH WATER BY-PASS AND SELF-PRIMING FUNCTION.
CITY WATER REQUIRED IS 160 GPM @ 40 PSIG

ELECTRICAL REQUIREMENTS

ONE (1) 208/230 VAC OR 460/480 VAC, 3 PHASE, 30 AMP CIRCUIT AND ONE (1) 120 VAC, 1 PHASE, 20 AMP CIRCUIT

CONDUIT

ONE (1) 1" CONDUIT FROM RECLAIM EQUIPMENT CONTROL BOX TO FRONT OF THE LAST TANK (FOR FLOATS)
ONE (1) 1/2" CONDUIT FROM EACH CARWASH EQUIPMENT CONTROL BOX TO SEND CONTROL VOLTAGE SIGNAL TO PURWATER'S REPRESSURIZATION POWER BOX, CONTROL WIRING FROM CARWASH CONTROLLER (110V IS DEFAULT) TO BE WIRED INTO CONTROL BOX ON FRAME

TANK CONFIGURATION RECOMMENDATION

FOUR TANK CONFIGURATION

 

 
PW 400-5M24O
  • VFD DRIVEN CONTINUOUS DUTY MOTOR 
  • SELF PRIMING PUMP 
  • HIGH EFFICIENCY CYCLONIC SEPARATORS 
  • CONTROL SIGNAL ACTIVATION 
  • 5 MICRON WATER OUTPUT 
  • CONTINUOUS SPARGING RECIRCULATION TECHNOLOGY FOR ODOR CONTROL 
  • POWDER COATED FRAME 
  • ODOR CONTROL OPTIONS
RECLAIM MAX. OUTPUT
150 GPM

RECLAIM PUMP
10 HP SELF-PRIMING CENTRIFUGAL PUMP
DRAWS 25 AMPS AT 208/230 VAC OR
DRAWS 12.5 AMPS AT 460/480 VAC
CUSTOMER TO SPECIFY VOLTAGE

DIMENSIONS

60" WIDTH X 76" TALL X 24" DEEP

NET (CRATED) WEIGHT 
1000 LBS

PLUMBING CONNECTIONS
TWO (2) 3" PVC SUCTION LINES, ONE FOR USE AND ONE FOR SPARE, TO COME UP FROM SETTLING TANKS TO THE RIGHT OF THE RECIRCULATION WITH 3" PVC FULL FLAPPER CHECK VALUES AT END 3" UNIONS ABOVE WATER LINE. 
ONE 2" LINE OUT TO THE WASH MANIFOLD
ONE 1" LINE TO RETURN TO THE SECOND CHAMBER OF THE RECLAIM TANK FOR OZONE ODOR CONTROL
ONE 1" LINE TO RETURN TO THE CATCH BASIN FOR THE UNDERFLOW OF THE PURWATER SUCCESSION FILTERS

ELECTRICAL REQUIREMENTS

ONE (1) 208/230 VAC OR 460/480 VAC
3 PHASE, 20 AMP CIRCUIT AND
ONE (1) 120 VAC, 1 PHASE, 20 AMP CIRCUIT

CONDUIT

(1) 1" CONDUIT FROM RECLAIM EQUIPMENT CONTROL BOX TO FRONT OF THE LAST TANK (FOR FLOATS)
(1) 1/2" CONDUIT FROM EACH CARWASH EQUIPMENT CONTROL BOX TO SEND CONTROL VOLTAGE SIGNAL TO PURWATER'S REPRESSURIZATION POWER BOX, CONTROL WIRING FROM CARWASH CONTROLLER (110V IS DEFAULT) TO BE WIRED INTO CONTROL BOX ON FRAME

TANK CONFIGURATION RECOMMENDATION

FOUR TANK CONFIGURATION

 

 
Contact us for more information and pricing 407-770-1000 or Toll Free 1-855-225-2700